LEED Habitat: Targeted Air-Sealing & Pre-Drywall Inspection

It has now been a little over 4 months since the project was started & yes, things are running a tad behind schedule. As I recall the completion date was originally scheduled for the end of this...

View Article



Notes from the Field: A tale of two reports & getting your money’s worth

Infrared Thermography is a very interesting field and if variety is the spice of life, who can argue with spending one day in the mechanical rooms of a hospital and the next seeing everything that goes...

View Article

Infrared Fun

Sometimes one just needs a laugh or head scratcher, so in honor of April Fool’s Day here are a few cool, funny, & head scratching infrared pics we had… So, hot off the press our newest post… I...

View Article

Alabama’s New Duct testing requirement goes into effect???

As many know Alabama adopted a new Residential Building & Energy Code which went into effect last October. One part of this was a delay placed on when the mandatory duct testing, insulation &...

View Article

Notes from the field: Always double check your settings

When one starts off doing energy audits, it generally takes them awhile to get a set system in place so they don’t forget a step. One of the biggest issues for many is making sure there diagnostic...

View Article


Basic Energy Audit Questionnaire & Checklists

Recently it was brought up that we should post a Basic Audit Questionnaire & Checklist like we did for Kitchens & Baths. The biggest issue with this though is that many questionnaires are...

View Article

Guest Post: The future of building codes & green building programs

First off I would like to thank Christopher Hill of Construction Law Musings for allowing me the opportunity to post on his site for a fourth time. I really am honored & humbled by the invitation....

View Article

Notes from the field: Single Point Test & TecTite

When completing Code Compliance Testing or doing a “Verified” Rating one has two options when it comes to Blower Door Tests. Today we are going to look at the single point test (802.5) using a...

View Article


Notes from the field: Multi Point Test

In our area, some code jurisdictions are now requiring a “multi-point” blower door test, instead of the more standard & improved “single-point” test for code compliance verifications. For many that...

View Article


Notes from the Field: The AHRI Directory

The AHRI’s (Air Conditioning, Heating, & Refrigeration Institute) directory is an awesome tool & can even be considered a god-send by many. Why & what is it? The AHRI is a globally...

View Article